AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve

Brand Name : Brando

Model Number : DMF-Y-62S

Certification : CE

Place of Origin : CHINA

MOQ : one set

Price : Negotiation

Payment Terms : T/T, Western Union, L/C, MoneyGram, D/P, D/A

Supply Ability : 150000 pieces per month

Delivery Time : Negotiation

Packaging Details : Inner Box,Carton,Pallet

Port size : G 2 1/2'' Inch

Number of diaphragm : 2

Media : Clean Air

Application : Dust cleaner equipment

Material : Aluminum

Power : Solenoid,Pneumatic

Pressure : 0.3MPa~0.6MPa

Structure : Diaphragm

Temperature of media : -35℃~+45℃

Voltage : AC110V/AC220V/DC24V/12VDC

Contact Now

AC220V DC 24V 2 1/2'' Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve

Description:

Working principle
Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.

Pulse jet valve installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4, Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid.
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.


Technical data chart of DMF Y series solenoid pulse valves in industrial filter use:

Model Numbers DMF-Y-25 DMF-Y-40S DMF-Y-50S DMF-Y-62S DMF-Y-76S DMF-Y-102S

Port size

G1'' G1 1/2''

G2''

G2 1/2''

G3''

G4''

Membrane sizes
(φ66 smaller)
φ96 φ112 φ160 φ188 φ202 φ255
CV values 30.53 53.47 71.47 150.85 186.66 313.09
Blowing area (m2) 8-10 12-16 18-28 27-38 37-65' 70-90
Weighgt (kg) 0.75 1.2 2.35 3.2 4.05 6.65
Environment Temperature -25℃-80℃ or customized
Relative Humidity ≤85%
Working Medium Clean Air
Protection class IP 65
Service life cycle Over million times
Voltages AC110V/AC220V/DC12V/DC24V/12VDC


Overall dimension of DMF-Y-62S Pneuamtic Pulse Solenoid Valve Aluminum Body for Dust Collector:
AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve

Detail Images Of DMF Series Control Solenoid Valve:
AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve
Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly)

Youtube video of DMF Dust Collector Pulse Solenoid Valve


Working place view of DMF clean air solenoid pulse jet valve single diaphragm:
AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve

Common faults and repair methods of DMF membrane pulse solenoid valve:
1. The spring is damaged. The spring on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blow port for a long time. The treatment method is to replace the spring.

2. the valve core dirt, because the intake air is not clean, causing the fouling of the valve core, resulting in the appearance of long-term intake of the nozzle or the pulse valve does not work after the power, the treatment method is to clean the valve core.

3. the diaphragm is damaged, after long-term work, the diaphragm is easy to fatigue, oxidation, etc., resulting in the appearance of long-term deflation of the pressure relief port, the pulse valve does not work, the treatment is to replace the diaphragm.

4. The rubber pad is damaged. After the use time is long, the rubber pad on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blowing port for a long time. The treatment method is to replace the rubber pad.

5. The orifice is blocked or damaged. The intake air is not clean and the throttle hole is blocked. The appearance is that the pulse valve is deflated to the nozzle for a long time. The treatment method is to clean the orifice; the orifice is damaged or missing, and the orifice is made. Loss of interception, resulting in abnormal pressure relief, the appearance of the pulse valve after the power is activated, the pressure relief port deflation, but the pulse valve is not sprayed, the treatment is a replacement orifice.

Focus on your demands, Offer you best solution:

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

Welcome to your any question and inquiry!


Product Tags:

pulse jet valves

      

solenoid pulse valve

      
Buy cheap AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve product

AC220V DC 24V 2 1/2" Inch DN62 Double Diaphragms DMF-Y-62S Electromagnetic Pulse Control Valve Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Brando Hardware Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)